• Video
  • |
  • WeChat
    WeChat

    scan

  • |
  • TEL:13725562312 / 0769-85830818

ion net

Model:KP6001A

KP6001A ion net is a static elimination device developed and produced by Kapal Company to eliminate static electricity on the surface of objects. The KP6001A ion net can generate a large amount of airflow with positive and negative charges, which can neut
application area
ion net

Product overview

Kp6001a ion net is a static electricity removing device developed and produced by kapar company to eliminate static electricity on the surface of objects.

Kp6001a ion net can produce a large amount of air flow with positive and negative charges, which can neutralize the charges on the object. When the object surface is negatively charged, it will attract the positive charge in the air flow. When the object surface is positively charged, it will attract the negative charge in the air flow, so as to neutralize the static electricity on the object surface and achieve the purpose of eliminating static electricity.

Kp6001a ion network is widely used in precision electronics, electronic assembly, pharmaceutical manufacturing and assembly, packaging and other industries.

Product features

*Eliminate static electricity quickly.

*Wide area for removing static electricity.

*Ion network has good grounding protection function.

Technical parameter

Input voltage

220V/50Hz or 110V/60Hz

The output voltage

AC 5.6KV

Ion balance  

≤|±50V|(150mm from the test center in front of the fan)

Power down time  

≤2S(150mm from the test center in front of the fan)

Operating temperature  

0℃-50℃

Working humidity

<75%

High voltage wire length

2M

Ozone concentration

≤ 0.03 ppm (150mm from the test center in front of the fan)

Dimensions

Customized according to customer requirements

Test result

Test Conditions

humidity:≤60%         Test voltage:1KV-100V        ambient temperature:22℃

distance

300mm

Neutralization time

just

1.1s

burden

1.2s

residual voltage

≤±50V


*The test instrument shall be me268a electrostatic comprehensive tester, and the test results shall prevail.

*Test according to iec-61340-5-1 a · 6.

*The test data will be different due to the surrounding temperature and humidity changes.