Product overview
TH2001B-L high-frequency ion air nozzle is a fixed static elimination device developed and produced by Kapal Company to eliminate static electricity and dust on the surface of objects. Compressed air is required for use.
TH2001B-L high-frequency ion air nozzle applies today's international new technology, adopts a small high-voltage transformer, converts the input DC power into high-frequency low-voltage AC power, without external high-voltage components and high-voltage wiring, and can easily add different components, application on different occasions. The TH2001B-L high-frequency ion air nozzle can generate a large amount of air flow with positive and negative charges, which is blown out at a high speed by the compressed air, which can neutralize the charge on the object. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. purpose of static electricity.
TH2001B-L high frequency ion air nozzle is widely used in machinery equipment, medical equipment manufacturing, electronic assembly, semiconductor manufacturing and other industries.
Product features
* The generated ion density is high, and the static electricity removal speed is fast. .
* The ion airflow covers a large area.
* Small size, light weight and easy installation.
* With indicator light alarm function.
* The air nozzles are available with a straight front outlet with a tube, a side outlet with a tube, a straight front outlet with an elbow, and a straight outlet without a tube.
* The air nozzle has a good grounding protection function.
Test result
Test Conditions | ||
Humidity: ≤60% Test voltage: 1KV-100V Ambient temperature: 22℃ | ||
distance | 300mm | |
just | 0.7s | |
burden | 0.8s | |
residual voltage | ≤|±15V| |
* The test results of the test instrument using ME268A electrostatic comprehensive tester shall prevail.
* Tested according to IEC-61340-5-1 A·6.
* Tested data may vary due to changes in ambient temperature and humidity.