• Video
  • |
  • WeChat
    WeChat

    scan

  • |
  • TEL:13725562312 / 0769-85830818

KP5002A ion wind copper rod

Model:KP5002A

Principle of action: KP5002A ion wind copper rod can generate a large amount of airflow with positive and negative charges, which can neutralize the charge on the object. When the charge on the surface of the object is negative, it will attract the positi
application area
KP5002A ion wind copper rod

Product overview

How it works:

      KP5002A ion wind copper rod can generate a large amount of airflow with positive and negative charges, which can neutralize the charge on the object. When the charge on the surface of the object is negative, it will attract the positive charge in the airflow. When the charge on the surface of the object is positive, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and the purpose of eliminating static electricity is achieved.

Ionizing device:

      The ionization device forms a stable high-intensity electric field under the action of low current and high voltage generated by the high-voltage generator, ionizes the air to form ions, and is carried out by the high-voltage airflow to the surface of the object to achieve the purpose of neutralizing static electricity and removing dust.


Product features

· Neutralizes static electricity quickly.

·Ion airflow covers a large area.

·Sturdy housing, easy to install, copper material.

·The copper rod has good grounding protection.

·Applicable to various harsh working environments.

Application range:

Processing and manufacturing of various sheet materials, plastic processing, winding processing, printing, packaging industries, etc.


Technical parameter

Operating Voltage

110V/60Hz  or  220V/50Hz

The output voltage

5.6KV

Ambient use temperature

0-50℃

weight

1.6kg/M

Rod length (maximum length)

3M(Can be customized according to customer requirements)

High voltage line length

3M

Pipe diameter

Φ32MM

Test result

Test condition RH: 60% Test temperature: 22℃ Test voltage: 5KV-500V

distance

30mm

150mm

300mm

Neutralization time

just

0.3s

1.3s

1.6s

burden

0.4s

1.2s

1.7s

* The test results of the test instrument using ME268A electrostatic comprehensive tester shall prevail.

* Tested according to IEC-61340-5-1 A·6.

* Tested data may vary due to changes in ambient temperature and humidity.