Product overview
KP3002 ion air gun is a hand-held electrostatic and dust removal device developed and produced by Kapal Company to eliminate static electricity and dust on the surface of objects. Compressed air is required for use.
The KP3002 ion air gun can generate a large amount of airflow with positive and negative charges, which is blown out at high speed by the compressed air, which can neutralize the charge on the object. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. purpose of static electricity.
KP3002 ion air gun is widely used in purification workshop, electronics, optical components, crystal processing and other industries.
Product features
* Neutralize static electricity quickly.
* The ion airflow covers a large area.
* Stable performance and easy installation.
* Synchronous control of high voltage and air output.
* The air gun comes with a regulator, which can adjust the air pressure arbitrarily.
* Equipped with ion indicator light and built-in air filter.
* The air gun has a good grounding protection function.
Technical parameter
Input voltage | 220V/50Hz or 110V/60Hz |
The output voltage | AC 5.6KV |
current consumption | ≤1.8A |
Air supply connector | Ф8mm(Customized according to customer requirements) |
Ion balance | ≤|±15V|(300mm from the front test center of the air gun) |
Power down time | ≤2S(300mm from the front test center of the air gun) |
use medium | clean compressed air |
Operating temperature | 0℃-50℃ |
Working humidity | <75% |
compressed air pressure | 0.3-0.8Mpa |
Air velocity | 10m/S |
noise | ≤65dB |
Ozone concentration | ≤ 0.03 ppm (150mm from the front center of the air outlet) |
weight | About 4.2kg |
Test result
Test Conditions | ||
Humidity: ≤60% Test voltage: 1KV-100V Ambient temperature: 22℃ | ||
distance | 300mm | |
Neutralization time | just | 0.7s |
burden | 0.8s | |
residual voltage | ≤±15V |
* The test results of the test instrument using ME268A electrostatic comprehensive tester shall prevail.
* Tested according to IEC-61340-5-1 A·6.
* Tested data may vary due to changes in ambient temperature and humidity.